Sugar Factory Tubes Sheet Ligaments
The ligament on a tube sheet is the material between two tube holes. In a perfect world the all the ligaments on a tube sheet will be exactly the sime size. However due to the variation in hole size due to tolerance and also due to mistakes in hole centre positioning there may be ligaments which are smaller than the theoretically calculated ligament. Now if it is found that on a particular tube sheet one or more of the ligaments is smaller than the others are we to reject the tube sheet and all the work done on it? If the tube sheet is rejected, the manufacturing programme will be delayed, and costs incurred.
The Tubular Exchanger Manufacturers Association (TEMA) has guidelines on minimum allowable ligaments on tube sheets. Unfortunately their recommendations only go up to 2 inch OD tubes, and so some extrapolation for 4 inch tubes is required.
| tube dia [inch] | tube pitch [inch] | maximum hole diameter [inch] | nominal ligament [inch] | minimum permissible ligament [inch] | ||
|---|---|---|---|---|---|---|
| dt | p | p/dt | p-dt | dh | p-dh | |
| 0.250 | 0.313 | 1.250 | 0.063 | 0.259 | 0.054 | 0.025 |
| 0.250 | 0.375 | 1.500 | 0.125 | 0.259 | 0.116 | 0.060 |
| 0.375 | 0.500 | 1.330 | 0.125 | 0.384 | 0.116 | 0.060 |
| 0.375 | 0.531 | 1.420 | 0.156 | 0.384 | 0.147 | 0.075 |
| 0.500 | 0.625 | 1.250 | 0.125 | 0.510 | 0.115 | 0.060 |
| 0.500 | 0.656 | 1.310 | 0.156 | 0.510 | 0.146 | 0.075 |
| 0.500 | 0.688 | 1.380 | 0.188 | 0.510 | 0.178 | 0.090 |
| 0.625 | 0.781 | 1.250 | 0.156 | 0.635 | 0.146 | 0.075 |
| 0.625 | 0.813 | 1.300 | 0.188 | 0.635 | 0.178 | 0.090 |
| 0.625 | 0.875 | 1.400 | 0.250 | 0.635 | 0.240 | 0.120 |
| 0.750 | 0.938 | 1.250 | 0.188 | 0.760 | 0.178 | 0.090 |
| 0.750 | 1.000 | 1.330 | 0.250 | 0.760 | 0.240 | 0.120 |
| 0.750 | 1.063 | 1.420 | 0.313 | 0.760 | 0.303 | 0.150 |
| 0.750 | 1.125 | 1.500 | 0.375 | 0.760 | 0.365 | 0.185 |
| 0.875 | 1.094 | 1.25 | 0.219 | 0.885 | 0.209 | 0.105 |
| 0.875 | 1.125 | 1.290 | 0.250 | 0.885 | 0.240 | 0.120 |
| 0.875 | 1.188 | 1.360 | 0.313 | 0.885 | 0.303 | 0.150 |
| 0.875 | 1.250 | 1.430 | 0.375 | 0.885 | 0.365 | 0.185 |
| 1.000 | 1.250 | 1.250 | 0.250 | 1.012 | 0.238 | 0.120 |
| 1.000 | 1.313 | 1.310 | 0.313 | 1.012 | 0.301 | 0.150 |
| 1.000 | 1.375 | 1.380 | 0.375 | 1.012 | 0.363 | 0.185 |
| 1.250 | 1.563 | 1.250 | 0.313 | 1.264 | 0.299 | 0.150 |
| 1.500 | 1.875 | 1.250 | 0.375 | 1.518 | 0.357 | 0.180 |
| 2.000 | 2.500 | 1.250 | 0.500 | 2.022 | 0.478 | 0.250 |
Standard Ligaments
96% of ligaments shall be greater than
ligstd = p - dh - (0.0032 t / dt in + 0.030 in)
where t = tube sheet thickness
Minimum Permisible Ligament
No ligamant shall be less than
ligmin = -0.0010465 + 0.510467 · (p-dh)
The factors in the above formula come from a linear regression of the data in the table above.
Example 1
In this example we consider a 2 in kestner evaporator type tube
- tube plate thickness
- t = 25 mm
- tube outside diameter
- dt = 2 in
dt = 50.8 mm - maximum tube hole dia
- dmax = 51.48 mm
- tube hole pitch
- p = 70 mm
- Drill drift tolerance
- toldd = 0.0016 in · t / dt
toldd = 0.02 in - standard ligament
- lstd = p - dmax - (2 · toldd + 0.030 in)
lstd = 17.72 mm - minimum ligament
- lmin = 0.0010465 mm + 0.5067383 · (p - dmax)
lmin = 9.38 mm
Example 2
In this example we consider a 4 in continuous vacuum pan type tube
- tube plate thickness
- t = 25 mm
- tube outside diameter
- dt = 4 in
dt = 101.6 mm - maximum tube hole dia
- dmax = 102.63 mm
- tube hole pitch
- p = 120 mm
- Drill drift tolerance
- toldd = 0.0016 in · t / dt
toldd = 0.01 in - standard ligament
- lstd = p - dmax - (2 · toldd + 0.030 in)
lstd = 16.59 mm - minimum ligament
- lmin = 0.0010465 mm + 0.5067383 · (p - dmax)
lmin = 8.78 mm